Automate Nucleic Acid Quantification
with Biomek i-Series Liquid Handlers
Quantifying nucleic acids is a critical step in molecular workflows—but it doesn’t have to slow you down. By integrating HSE•AG’s eviFluor Duo Fluorometer and eviDense UV Photometer directly onto the deck of Biomek i‑Series Liquid Handlers, you can measure, process, and act on data in real time.
These optional modules enable immediate, decision-based pipetting and support smarter, automated workflows—streamlining sample preparation and improving data quality without added complexity.
Explore HSE•AG’s Quantification Modules in Depth
eviDense UV Photometer
- Absorbance-based quantification using UV-Vis spectrophotometry
- Measures directly at the pipette tip using microcuvette technology
- Four wavelengths: 230, 260, 280, and 340 nm
- Preserves sample integrity with fixed pathlength and evaporation-resistant microcuvette design
- Handles sample volumes of 10 µL
- Processes up to 192 samples without a refill
eviFluor Duo Fluorometer
- Fluorescence-based quantification with dual-channel sensitivity
- Measures directly at the pipette tip using microcuvette technology
- Excitation: 470/625 nm | Emission: 520/680 nm
- Handles sample volumes as low as 1 µL
- Processes up to 288 samples without a refill
Your Benefits at a Glance
Accelerating lab results
In-process measurements eliminate manual interventions—maximizing walk-away time and increasing overall lab efficiency.
![]()
Precision and reliability
The microcuvette ensures a fixed pathlength and eliminates evaporation errors. Automated, on-deck measurements deliver consistent results and reduce errors resulting from manual handling.
Intelligent data handling
Integrated sample identification, data capture, and transfer enhance traceability and eliminate transcription errors.
Space saving
The modules fit into a standard SBS plate position, requiring minimal space and allowing seamless integration into liquid handlers.
![]()
Cost savings
No waste plates, no additional software licensing, miniaturized reactions.
![]()
Sample recoverability
After measurement with the eviDense UV Photometer, the sample can be easily recovered and used in further applications.
Explore More Insights
Products not intended or validated for use in the diagnosis of disease or other conditions.
Beckman Coulter makes no warranties of any kind whatsoever express or implied, with respect to this the illustrated applications, including but not limited to warranties of fitness for a particular purpose or merchantability or that these are non-infringing. All warranties are expressly disclaimed. Your use of the method is solely at your own risk, without recourse to Beckman Coulter. These illustrated applications are for demonstration only; and is not validated by Beckman Coulter.